The Get ComProbe Information command is sent to the datasource to get the serial number and hardware version of the Sodera, X240, X500, X500e or X700. The command format is:
“Get ComProbe Information”
Response: “GET COMPROBE INFORMATION;<status>;Reason=<reason>” where reason will be supplied for SUCCEEDED and FAILED status.
For SUCCEEDED status, reason will be “serial_number=<hardware serial number>|hardware_version=<hardware version>”